BYOS (Build your own shelter) kit

bolt together

save big bucks!

easy to assemble  /   EF-5 certified / powder coated

Protection You Can Build On

Easy to Assemble – No welding required! Just bolt the panels together.
Heavy-Duty Steel – Made from steel for maximum protection.
EF-5 Rated – Engineered to withstand the strongest tornadoes.
Outdoor & Indoor Use – Can be installed in a garage, basement, or backyard.

Sizes

SIZE OCCUPANCY $ PRICE
6’x3’x6.5′
 6 person
$3.950
6’x4’x6.5′
 8 person
$4.250
6’x5’x6.5′
 10 person
$4.850
6’x6’x6.5′
 12 person
$5.450
6’x7’x6.5′
 14 person
$6.500
SIZE OCCUPANCY $ PRICE
6’x8’x6.5′
 16 person
$7.100
6’x9’x6.5′
 18 person
$7.700
6’x10’x6.5′
 20 person
$8.300
6’x11’x6.5′
 22 person
$8.900
6’x12’x6.5′
 24 person
$9.500

Prices do not include delivery or taxes 

Technical specs

Tough as Steel, Easy to Assemble

1. All documentation provided meets or exceeds the FEMA P320 MARCH 2021 Fifth Edition, FEMA P-361 APRIL 2021 Fourth Edition, and the 2020 ICC 500 ICC/NSSA ventilation, design, and construction standards.

2. All Welding shall conform to the standards of the American Welding Society. Electrodes for all shop and field welds shall be E70 0.35″ thick wire, with a short arc process.

3. Saferooms must meet or exceed the FEMA P-320 MARCH 2021 Fifth Edition, FEMA P-361 APRIL 2021 Fourth Edition, and the 2020 ICC 500 ICC/NSSA standards for the design and construction of saferooms.

4. All panels skin material’s thickness to be 3/16″.

5. All internal door’s bracing shall be 3/16″ Thickness.

6. All material is ASTM A36 Steel unless noted.

7. Assembly Carriage Bolts shall be 1/2″-13 x 1-1/4″ CARRIAGE BOLT ZINC GRADE 5.

8. The anchoring system shall be 3/4″ Diam Hilti Expansion/Epoxy Anchors.

9. Saferooms are to be manufactured using a minimum 3/16″ panel / door skin thickness.

10. 1/2″ is the maximum change in threshold level for the door. Thresholds exceeding 1/4″ must be beveled.

11. The minimum bending fillet radius for steel plates should be determined based on the manufacturer’s criteria and capabilities.

1. Air intakes: Qty= 2 Total ventilation= 51 Sq in.

2. Mount on door: Qty= x1 Total ventilation through door’s threshold = 28 Sq in.

Total unit ventilation= 79 Sq In.

Minimun of 2 Sq in. needed per person for residential shelters according the 2020 ICC 500. Please refer to the article 702.4.1

FOR RESIDENTIAL TORNADO SHELTERS:

1. For natural ventilation, a minimum of 2 square inches per person is required, according to the 2020 ICC 500. Please refer to article 702.4.1.

2. A minimum of 3 square feet per person is required for the total shelter’s capacity and size. Type of occupants, One- and two-family dwelling.

B'Safe Shelters ® ™. “America’s #1 Tornado Safety Brand”Contact us & Discover How Much You Can Save
B'Safe Shelters ® ™. “America’s #1 Tornado Safety Brand”
We Deliver all over the US

CALL US TODAY